Can You Build a Legal Triple-Decker?
You own an empty 40′ × 100′ (4,000 sq. ft.) residential lot in Allston-Brighton’s Three-Family Residential (3F-4000) zoning subdistrict, flanked by two classic Boston triple-deckers built around 1910 (before zoning existed). Draw a building box in the empty lot and add stories to see if you can build a 3-family home without violating a zoning rule.
Interactive Lot Plan (Top-Down View)
Streetscape Elevation View (Stories & 35′ Height Limit)
Building & Story Controls
Empty LotArticle 51 (3F-4000) Zoning Compliance
Allston-Brighton Neighborhood District • Three-Family Residential
Why Is It Impossible to Build a Triple-Decker Here?
Even though this lot is in Allston-Brighton’s Three-Family Residential (3F-4000) subdistrict and is flanked by two existing triple-deckers on identical 40′ × 100′ lots, Boston’s zoning rules create an inescapable Catch-22:
4,000 sq. ft. Only Allows 2 Units—A 3rd Unit Requires 6,000 sq. ft.!
Despite being named 3F-4000, the dimensional table specifies 4,000 sq. ft. minimum lot area for 1 or 2 units, plus 2,000 additional sq. ft. for each additional unit (requiring 6,000 sq. ft. for 3 units and 8,000 sq. ft. for 4 units). Classic 4,000 sq. ft. triple-decker lots are banned from having a 3-family home unless you drop down to 1 or 2 units.
20′ Front + 30′ Rear + 15′ Side Setbacks Carve Up the Lot
Pre-zoning triple-deckers sit 10 feet from the street and 4 feet from side lot lines. Today’s rules demand a 20-foot front yard, 30-foot rear yard, 10 feet of separation from neighboring buildings, and 15 feet of combined side yards—shrinking a 40′ wide lot down to a 25′ wide buildable strip.
A 0.8 Floor Area Ratio Caps Total Space at 3,200 sq. ft.
Even inside the 25′ × 50′ setback box (1,250 sq. ft./floor), a 3-story building totals 3,750 sq. ft. (0.94 FAR)—violating the 0.80 maximum FAR (3,200 sq. ft.) and the 1,950 sq. ft. Usable Open Space requirement (650 sq. ft. per unit outside the front yard).